Plug-In Charge Control System
PLUG-IN CHARGE CONTROL SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION [01/2023 - 11/2023]
| DTC Code | Description |
|---|---|
| P060B-1C | DC Quick Charging Control Module A/D Processing Circuit Voltage Out of Range |
| P060B-49 | Plug-in Control Module A/D Processing Internal Electronic Failure |
| P060B-71 | DC Quick Charging Control Module A/D Processing Actuator Stuck |
| P0688-1F | DC Quick Charging Control Module Power Relay Sense Circuit Intermittent |
| P0D07-00 | Hybrid/EV Battery Charging System Positive Contactor Stuck Closed |
| P0D07-73 | Hybrid/EV Battery Charging System Positive/Negative Contactor Actuator Stuck Closed |
| P0D0E-73 | Hybrid/EV Battery Charging System Negative Contactor Control Actuator Stuck Closed |
| P0D2A-19 | Hybrid/EV Battery Charger Input Current Sensor Circuit Circuit Current Above Threshold |
| P0D38-12 | Hybrid/EV Battery Charger Input Current Sensor Circuit Circuit Short to Auxiliary Battery |
| P0D38-14 | Hybrid/EV Battery Charger Input Current Sensor Circuit Circuit Short to Ground or Open |
| P0D38-28 | Hybrid/EV Battery Charger Input Current Sensor Circuit Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0D38-9E | Hybrid/EV Battery Charger Input Current Sensor Overcurrent Detection Circuit Stuck On |
| P0D4C-12 | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Circuit Short to Auxiliary Battery |
| P0D4C-14 | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Circuit Short to Ground or Open |
| P0D4C-1C | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Voltage Out of Range |
| P0D56-11 | Charging Connector Proximity Detection Circuit Short to Ground |
| P0D56-15 | Charging Connector Proximity Detection Circuit Short to Auxiliary Battery or Open |
| P0D5E-00 | Hybrid/EV Battery Charger Hybrid/EV System Discharge Time Too Long |
| P0D99-11 | Hybrid/EV Battery Charger Coupler Temperature Sensor "A" Circuit Low Circuit Short to Ground |
| P0D99-15 | Hybrid/EV Battery Charger Coupler Temperature Sensor "A" Circuit High Circuit Short to Auxiliary Battery or Open |
| P0E5E-49 | Hybrid/EV Battery Charger Control Module Internal Electronic Failure |
| P0E5E-87 | Plug-in Control Module Processor from Hybrid/EV Battery Charger Control Module Processor Missing Message |
| P0E61-9E | Hybrid/EV Battery Charger Enable Circuit Stuck On |
| P0E6A-73 | Hybrid/EV Battery Charging System Precharge Contactor Control Actuator Stuck Closed |
| P0EE7-11 | Hybrid/EV Battery Charger Coupler Temperature Sensor "B" Circuit Low Circuit Short to Ground |
| P0EE7-15 | Hybrid/EV Battery Charger Coupler Temperature Sensor "B" Circuit High Circuit Short to Auxiliary Battery or Open |
| P0EF7-16 | Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit Low Circuit Voltage Below Threshold |
| P0EF7-17 | Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit High Circuit Voltage Above Threshold |
| P0EF7-28 | Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit Range/Performance Signal Bias Level Out of Range / Zero Adjustment Failure |
| P1688-49 | Hybrid/EV Battery Charger Control Module I/F Processor Internal Electronic Failure |
| P1689-49 | Hybrid/EV Battery Charger Control Module I/F Processor A/D Processing Internal Electronic Failure |
| P19D0-14 | Hybrid/EV Battery Charger Control Module "A" Sensor Power Supply "A" Circuit Short to Ground or Open |
| P19D3-14 | Hybrid/EV Battery Charger Control Module "A" Sensor Power Supply "B" Circuit Short to Ground or Open |
| P19D6-62 | DC Charging Inlet Temperature Sensor "A" / "B" Signal Compare Failure |
| P19D7-62 | DC Relay Temperature Sensor "A" / "B" Signal Compare Failure |
| P19D8-11 | DC Relay Temperature Sensor "A" Circuit Short to Ground |
| P19D8-15 | DC Relay Temperature Sensor "A" Circuit Short to Battery or Open |
| P19DC-11 | DC Relay Temperature Sensor "B" Circuit Short to Ground |
| P19DC-15 | DC Relay Temperature Sensor "B" Circuit Short to Battery or Open |
| P1A9E-1C | DC Charging Control Module A/D Processing (ch2) Circuit Voltage Out of Range |
| P1A9E-49 | DC Charging Control Module A/D Processing (ch2) Internal Electronic Failure |
| P1A9E-71 | DC Charging Control Module A/D Processing (ch2) Actuator Stuck |
| P1BD8-12 | Hybrid/EV Battery Charger Input Current Sensor "B" Circuit Short to Auxiliary Battery |
| P1BD8-14 | Hybrid/EV Battery Charger Input Current Sensor "B" Circuit Short to Ground or Open |
| P1BF8-62 | Hybrid/EV Battery Charger Coupler Temperature Sensor "A"/"B" Signal Compare Failure |
| P1C00-12 | Voltage Sensor after Boosting by PFC Boosting Circuit Circuit Short to Auxiliary Battery |
| P1C00-14 | Voltage Sensor after Boosting by PFC Boosting Circuit Circuit Short to Ground or Open |
| P1C00-16 | Voltage Sensor after Boosting by PFC Boosting Circuit Circuit Voltage Below Threshold |
| P1C00-9E | Voltage Sensor after Boosting by PFC Boosting Circuit Overvoltage Detection Circuit Stuck On |
| P1C05-12 | PFC Inverter Temperature Sensor Circuit Short to Auxiliary Battery |
| P1C05-14 | PFC Inverter Temperature Sensor Circuit Short to Ground or Open |
| P1C0A-12 | DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery |
| P1C0A-14 | DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open |
| P1C10-12 | Current after Boosting by PFC Boosting Circuit Circuit Short to Auxiliary Battery |
| P1C10-14 | Current after Boosting by PFC Boosting Circuit Circuit Short to Ground or Open |
| P1C10-28 | Current after Boosting by PFC Boosting Circuit Signal Bias Level Out of Range / Zero Adjustment Failure |
| P1C10-9E | Current Sensor after Boosting by PFC Boosting Circuit Overcurrent Detection Circuit Stuck On |
| P1C1B-00 | PFC Boosting Circuit Malfunction |
| P1C1C-00 | DC/DC Converter Malfunction (for Charging) |
| P1C1D-00 | Charging Power Low |
| P1C1E-00 | Charging Power High |
| P1C1F-49 | Hybrid/EV Battery Charger Control Module A/D Processing Internal Electronic Failure |
| P1C25-62 | PFC Inverter Temperature Sensor/DC/DC Converter for Charging Temperature Sensor Signal Compare Failure |
| P1C26-17 | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Circuit Voltage Above Threshold |
| P1C27-17 | Voltage Sensor after Boosting by PFC Boosting Circuit Circuit Voltage Above Threshold |
| P1C28-19 | Current after Boosting by PFC Boosting Circuit Circuit Current Above Threshold |
| P1CA4-00 | Charger Pre-charging Malfunction |
| P1CCD-96 | Sub DC/DC Converter (for Charging) Component Internal Failure |
| P1CCD-9E | Sub DC/DC Converter (for Charging) Stuck On |
| P1CCD-9F | Sub DC/DC Converter (for Charging) Stuck Off |
| P1CCE-12 | Sub DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery |
| P1CCE-14 | Sub DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open |
| P1CCE-1C | Sub DC/DC Converter Temperature Sensor (for Charging) Circuit Voltage Out of Range |
| P1CED-1C | Plug-in Control ECU Power Supply (Plus) Circuit Voltage Out of Range |
| P1CF0-1C | Plug-in Control ECU Power Supply (Minus) Circuit Voltage Out of Range |
| P1CF3-1C | Plug-in Control ECU Power Supply (Offset) Circuit Voltage Out of Range |
| P1E95-11 | DC Quick Charging Positive Inlet Temperature Circuit Short to Ground |
| P1E95-15 | DC Quick Charging Positive Inlet Temperature Circuit Short to Auxiliary Battery or Open |
| P1E9A-11 | DC Quick Charging Negative Inlet Temperature Circuit Short to Ground |
| P1E9A-15 | DC Quick Charging Negative Inlet Temperature Circuit Short to Auxiliary Battery or Open |
| P1F3D-04 | Charging Communication Module System Internal Failure |
| P2E90-00 | Hybrid/EV Battery Charger "A" Internal Power Supply Performance |
| P308F-49 | High Voltage Charging Circuit Short during Pre-Charge |
| P309F-49 | High Voltage Charging Circuit Consumption Circuit Short |
| P30C8-11 | DC Quick Charging Positive Relay Circuit Short to Ground |
| P30C8-15 | DC Quick Charging Positive Relay Circuit Short to Auxiliary Battery or Open |
| P313F-11 | DC Quick Charging Negative Relay Circuit Short to Ground |
| P313F-15 | DC Quick Charging Negative Relay Circuit Short to Auxiliary Battery or Open |
| P31E0-16 | Charging/Power Feeding Voltage Sensor Circuit Voltage Below Threshold |
| P31E0-17 | Charging/Power Feeding Voltage Sensor Circuit Voltage Above Threshold |
| P31E6-73 | DC Quick Charging Positive Relay Actuator Stuck Closed |
| P31E8-73 | DC Quick Charging Negative Relay Actuator Stuck Closed |
| P33CA-16 | DCVA Sensor Circuit Voltage Below Threshold |
| P33CA-17 | DCVA Sensor Circuit Voltage Above Threshold |
| P33CA-1C | DCVA Sensor Circuit Voltage Out of Range |
| U0155-87 | Lost Communication with Instrument Panel Cluster (IPC) Control Module Missing Message |
| U01BB-87 | Lost Communication with Battery Charger Control Module "B" Missing Message |
| U0293-87 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message |
| U113B-87 | Lost Communication with Charging Communication Module Missing Message |
| U1151-87 | Lost Communication with Hybrid/EV Powertrain Control Module (ch3) Missing Message |
| U117B-87 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" (ch2) Missing Message |
PLUG-IN CHARGE CONTROL SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION [11/2023 - ]
| DTC Code | Description |
|---|---|
| P060B-1C | DC Quick Charging Control Module A/D Processing Circuit Voltage Out of Range |
| P060B-49 | Plug-in Control Module A/D Processing Internal Electronic Failure |
| P060B-71 | DC Quick Charging Control Module A/D Processing Actuator Stuck |
| P0688-1F | DC Quick Charging Control Module Power Relay Sense Circuit Intermittent |
| P0D07-00 | Hybrid/EV Battery Charging System Positive Contactor Stuck Closed |
| P0D07-73 | Hybrid/EV Battery Charging System Positive/Negative Contactor Actuator Stuck Closed |
| P0D0E-73 | Hybrid/EV Battery Charging System Negative Contactor Control Actuator Stuck Closed |
| P0D2A-19 | Hybrid/EV Battery Charger Input Current Sensor Circuit Circuit Current Above Threshold |
| P0D38-12 | Hybrid/EV Battery Charger Input Current Sensor Circuit Circuit Short to Auxiliary Battery |
| P0D38-14 | Hybrid/EV Battery Charger Input Current Sensor Circuit Circuit Short to Ground or Open |
| P0D38-28 | Hybrid/EV Battery Charger Input Current Sensor Circuit Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0D38-9E | Hybrid/EV Battery Charger Input Current Sensor Overcurrent Detection Circuit Stuck On |
| P0D4C-12 | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Circuit Short to Auxiliary Battery |
| P0D4C-14 | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Circuit Short to Ground or Open |
| P0D4C-1C | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Voltage Out of Range |
| P0D56-11 | Charging Connector Proximity Detection Circuit Short to Ground |
| P0D56-15 | Charging Connector Proximity Detection Circuit Short to Auxiliary Battery or Open |
| P0D5E-00 | Hybrid/EV Battery Charger Hybrid/EV System Discharge Time Too Long |
| P0D99-11 | Hybrid/EV Battery Charger Coupler Temperature Sensor "A" Circuit Low Circuit Short to Ground |
| P0D99-15 | Hybrid/EV Battery Charger Coupler Temperature Sensor "A" Circuit High Circuit Short to Auxiliary Battery or Open |
| P0E5E-49 | Hybrid/EV Battery Charger Control Module Internal Electronic Failure |
| P0E5E-87 | Plug-in Control Module Processor from Hybrid/EV Battery Charger Control Module Processor Missing Message |
| P0E61-9E | Hybrid/EV Battery Charger Enable Circuit Stuck On |
| P0E6A-73 | Hybrid/EV Battery Charging System Precharge Contactor Control Actuator Stuck Closed |
| P0EE7-11 | Hybrid/EV Battery Charger Coupler Temperature Sensor "B" Circuit Low Circuit Short to Ground |
| P0EE7-15 | Hybrid/EV Battery Charger Coupler Temperature Sensor "B" Circuit High Circuit Short to Auxiliary Battery or Open |
| P0EF7-16 | Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit Low Circuit Voltage Below Threshold |
| P0EF7-17 | Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit High Circuit Voltage Above Threshold |
| P0EF7-28 | Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit Range/Performance Signal Bias Level Out of Range / Zero Adjustment Failure |
| P1688-49 | Hybrid/EV Battery Charger Control Module I/F Processor Internal Electronic Failure |
| P1689-49 | Hybrid/EV Battery Charger Control Module I/F Processor A/D Processing Internal Electronic Failure |
| P19D0-14 | Hybrid/EV Battery Charger Control Module "A" Sensor Power Supply "A" Circuit Short to Ground or Open |
| P19D3-14 | Hybrid/EV Battery Charger Control Module "A" Sensor Power Supply "B" Circuit Short to Ground or Open |
| P19D6-62 | DC Charging Inlet Temperature Sensor "A" / "B" Signal Compare Failure |
| P19D7-62 | DC Relay Temperature Sensor "A" / "B" Signal Compare Failure |
| P19D8-11 | DC Relay Temperature Sensor "A" Circuit Short to Ground |
| P19D8-15 | DC Relay Temperature Sensor "A" Circuit Short to Battery or Open |
| P19DC-11 | DC Relay Temperature Sensor "B" Circuit Short to Ground |
| P19DC-15 | DC Relay Temperature Sensor "B" Circuit Short to Battery or Open |
| P1A9E-1C | DC Charging Control Module A/D Processing (ch2) Circuit Voltage Out of Range |
| P1A9E-49 | DC Charging Control Module A/D Processing (ch2) Internal Electronic Failure |
| P1A9E-71 | DC Charging Control Module A/D Processing (ch2) Actuator Stuck |
| P1BD8-12 | Hybrid/EV Battery Charger Input Current Sensor "B" Circuit Short to Auxiliary Battery |
| P1BD8-14 | Hybrid/EV Battery Charger Input Current Sensor "B" Circuit Short to Ground or Open |
| P1BF8-62 | Hybrid/EV Battery Charger Coupler Temperature Sensor "A"/"B" Signal Compare Failure |
| P1C00-12 | Voltage Sensor after Boosting by PFC Boosting Circuit Circuit Short to Auxiliary Battery |
| P1C00-14 | Voltage Sensor after Boosting by PFC Boosting Circuit Circuit Short to Ground or Open |
| P1C00-16 | Voltage Sensor after Boosting by PFC Boosting Circuit Circuit Voltage Below Threshold |
| P1C00-9E | Voltage Sensor after Boosting by PFC Boosting Circuit Overvoltage Detection Circuit Stuck On |
| P1C05-12 | PFC Inverter Temperature Sensor Circuit Short to Auxiliary Battery |
| P1C05-14 | PFC Inverter Temperature Sensor Circuit Short to Ground or Open |
| P1C0A-12 | DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery |
| P1C0A-14 | DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open |
| P1C10-12 | Current after Boosting by PFC Boosting Circuit Circuit Short to Auxiliary Battery |
| P1C10-14 | Current after Boosting by PFC Boosting Circuit Circuit Short to Ground or Open |
| P1C10-28 | Current after Boosting by PFC Boosting Circuit Signal Bias Level Out of Range / Zero Adjustment Failure |
| P1C10-9E | Current Sensor after Boosting by PFC Boosting Circuit Overcurrent Detection Circuit Stuck On |
| P1C1B-00 | PFC Boosting Circuit Malfunction |
| P1C1C-00 | DC/DC Converter Malfunction (for Charging) |
| P1C1D-00 | Charging Power Low |
| P1C1E-00 | Charging Power High |
| P1C1F-49 | Hybrid/EV Battery Charger Control Module A/D Processing Internal Electronic Failure |
| P1C25-62 | PFC Inverter Temperature Sensor/DC/DC Converter for Charging Temperature Sensor Signal Compare Failure |
| P1C26-17 | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Circuit Voltage Above Threshold |
| P1C27-17 | Voltage Sensor after Boosting by PFC Boosting Circuit Circuit Voltage Above Threshold |
| P1C28-19 | Current after Boosting by PFC Boosting Circuit Circuit Current Above Threshold |
| P1CA4-00 | Charger Pre-charging Malfunction |
| P1CCD-96 | Sub DC/DC Converter (for Charging) Component Internal Failure |
| P1CCD-9E | Sub DC/DC Converter (for Charging) Stuck On |
| P1CCD-9F | Sub DC/DC Converter (for Charging) Stuck Off |
| P1CCE-12 | Sub DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery |
| P1CCE-14 | Sub DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open |
| P1CCE-1C | Sub DC/DC Converter Temperature Sensor (for Charging) Circuit Voltage Out of Range |
| P1CED-1C | Plug-in Control ECU Power Supply (Plus) Circuit Voltage Out of Range |
| P1CF0-1C | Plug-in Control ECU Power Supply (Minus) Circuit Voltage Out of Range |
| P1CF3-1C | Plug-in Control ECU Power Supply (Offset) Circuit Voltage Out of Range |
| P1E95-11 | DC Quick Charging Positive Inlet Temperature Circuit Short to Ground |
| P1E95-15 | DC Quick Charging Positive Inlet Temperature Circuit Short to Auxiliary Battery or Open |
| P1E9A-11 | DC Quick Charging Negative Inlet Temperature Circuit Short to Ground |
| P1E9A-15 | DC Quick Charging Negative Inlet Temperature Circuit Short to Auxiliary Battery or Open |
| P1F3D-04 | Charging Communication Module System Internal Failure |
| P2E90-00 | Hybrid/EV Battery Charger "A" Internal Power Supply Performance |
| P308F-49 | High Voltage Charging Circuit Short during Pre-Charge |
| P309F-49 | High Voltage Charging Circuit Consumption Circuit Short |
| P30C8-11 | DC Quick Charging Positive Relay Circuit Short to Ground |
| P30C8-15 | DC Quick Charging Positive Relay Circuit Short to Auxiliary Battery or Open |
| P313F-11 | DC Quick Charging Negative Relay Circuit Short to Ground |
| P313F-15 | DC Quick Charging Negative Relay Circuit Short to Auxiliary Battery or Open |
| P31E0-16 | Charging/Power Feeding Voltage Sensor Circuit Voltage Below Threshold |
| P31E0-17 | Charging/Power Feeding Voltage Sensor Circuit Voltage Above Threshold |
| P31E6-73 | DC Quick Charging Positive Relay Actuator Stuck Closed |
| P31E8-73 | DC Quick Charging Negative Relay Actuator Stuck Closed |
| P33CA-16 | DCVA Sensor Circuit Voltage Below Threshold |
| P33CA-17 | DCVA Sensor Circuit Voltage Above Threshold |
| P33CA-1C | DCVA Sensor Circuit Voltage Out of Range |
| U0155-87 | Lost Communication with Instrument Panel Cluster (IPC) Control Module Missing Message |
| U01BB-87 | Lost Communication with Battery Charger Control Module "B" Missing Message |
| U0293-87 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message |
| U113B-87 | Lost Communication with Charging Communication Module Missing Message |
| U1151-87 | Lost Communication with Hybrid/EV Powertrain Control Module (ch3) Missing Message |
| U117B-87 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" (ch2) Missing Message |