Inspection [09/2023 - ]: Procedure
- INSPECT NO. 1 TURBO PRESSURE SENSOR
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(No. 1 Turbo Pressure Sensor)Standard Resistance
Tester Connection Condition Specified Condition Result 4(THIM) - 2(E2) - 20°C (- 4°F) 14.6 to 17.8 kΩ kΩ 4(THIM) - 2(E2) 20°C (68°F) 2.21 to 2.69 kΩ kΩ 4(THIM) - 2(E2) 80°C (176°F) 0.290 to 0.354 kΩ kΩ If the result is not as specified, replace the No. 1 turbo pressure sensor.
- Measure the resistance according to the value(s) in the table below.