During Start-Up
- Ensure ignition timing is within specification.
- Inspect throttle body ports and valves for deposits, wear or plugging. Clean or replace as necessary.
- Connect inductive timing light to spark plug wire and check for weakness in flash.
- Ensure spark plug wires are within allowable resistance values.
- Check for spark using spark tester.
- Ensure engine has adequate compression.
- Remove canister purge line from intake and test drive vehicle.
- Remove vacuum hose from fuel pressure regulator. Apply vacuum and pressure and monitor symptom change.
- Disconnect exhaust gas sensor and monitor change in driveability. If it improves, replace sensor. If not, go to 10.
- Enter self-diagnostic Mode II and monitor fuel metering system operation.