DTC Confirmation Test
Malfunction is detected when improper voltage is sent to ECM from EVAP-CSPS. Possible causes are:
- EVAP-CSPS circuit open or shorted.
- Blockage or leak in hose to EVAP-CSPS.
- Defective EVAP-CSPS.
- Defective EVAP Canister Vent Control Valve (EVAP-CVCV).
- Defective EVAP Canister Purge Volume Control Valve (EVAP-CPVCV).
- Defective EVAP canister.
- Faulty hose between EVAP-CVCV and water separator.
CAUTION:
DO NOT use ECM ground terminals when measuring voltage.
To set DTC, start engine and warm to normal operating temperature. Measure voltage between ground and ECM terminal No. 63 (fuel tank temperature sensor signal) by backprobing. See Figure and Figure . Ensure voltage is less than 4.2 volts. Turn ignition off and wait at least 5 seconds. Start engine and wait at least 20 seconds. Select MODE 7 on scan tool. If first trip DTC is detected, go to PROCEDURE .