With CONSULT-II Scan Tool
- Turn ignition Off.
- Connect CONSULT-II to data link connector. See .
- Start engine.
- Drive vehicle over 20 MPH for at least one minute.
- Stop vehicle, leave engine running and touch START on CONSULT-II screen.
- Touch ABS.
- Touch SELF-DIAG RESULTS. The screen shows the detected malfunction and how many times the ignition switch has been turned since the malfunction.
- Make the necessary repairs following the diagnostic procedures.
- After all malfunctions are repaired, erase self-diagnostic results stored in the control unit by touching ERASE.
- Check ABS warning lamp for deactivation after driving vehicle over 20 MPH for at least one minute.