DTC Confirmation Test (Using Generic Scan Tool)
NOTE:
Use the following test to check overall function of EVAP control system purge flow monitoring. During this test, 1st trip DTC may not be confirmed.
- Raise drive wheels. Start engine (TCS switch in OFF position) and warm to normal operating temperature. Turn ignition off and wait at least 10 seconds.
- Start engine and wait at least 70 seconds. Measure and record voltage between ground and EVAP-CSPS signal circuit at ECM terminal No. 60 (White wire) by backprobing. See Figure and Figure .
- While monitoring voltage, maintain the following conditions for at least 1 minute:
- A/C switch: ON position.
- Steering wheel: fully turned.
- Headlight switch: ON position.
- Rear window defogger switch: ON position.
- Engine speed: about 3000 RPM.
- Transmission: any forward gear.
Voltage should remain 0.1 volt less than voltage measured at idle for at least 1 second.
- If voltage is as specified, system is okay at this time. If voltage is not as specified, go to DIAGNOSTIC PROCEDURE .