Ignition Signal: Wiring Diagram
WARNING: This page is about a different car, the 2006 Nissan Xterra. However, it is still accessible from the selected car via links, so may be relevant.
For PG Power or Section, go to SYSTEM WIRING DIAGRAMS .
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in damage to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
ECM GROUND TERMINALS INPUT/OUTPUT VOLTAGE REFERENCE
| TERMINAL NO. | WIRE COLOR | ITEM | CONDITION | DATA (DC Voltage) |
|---|---|---|---|---|
| 111 | BR | ECM relay (Self shut-off) |
[Engine is running] [Ignition switch: OFF]
|
0-1.5V |
[Ignition switch: OFF]
|
BATTERY VOLTAGE (11 -14V) | |||
| 119 120 | R P | Power supply for ECM | [Ignition switch: ON] | BATTERY VOLTAGE (11 -14V) |
For PG Power or Section, go to SYSTEM WIRING DIAGRAMS .
Specification data are reference values and are measured between each terminal and ground. Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in damage to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
ECM GROUND TERMINALS INPUT/OUTPUT VOLTAGE REFERENCE
| TERMINAL NO. | WIRE COLOR | ITEM | CONDITION | DATA (DC Voltage) | ||
|---|---|---|---|---|---|---|
| 60 61 62 |
SB L Y |
Ignition signal No. 5 Ignition signal No. 3 Ignition signal No. 1 |
[Engine is running]
NOTE:
The pulse cycle changes depending on RPM at idle
|
0 - 0.2V(1) | ||
[Engine is running]
|
0.1 -0.4V(1) | |||||
|
||||||
For PG Power or Section, go to SYSTEM WIRING DIAGRAMS .
Specification data are reference values and are measured between each terminal and ground. Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in damage to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
ECM GROUND TERMINALS INPUT/OUTPUT VOLTAGE REFERENCE
| TERMINAL NO. | WIRE COLOR | ITEM | CONDITION | DATA (DC Voltage) | ||
|---|---|---|---|---|---|---|
| 79 80 81 |
P GR G |
Ignition signal No. 6 Ignition signal No. 4 Ignition signal No. 2 |
[Engine is running]
NOTE:
The pulse cycle changes depending on RPM at idle
|
0 - 0.2V(1) | ||
[Engine is running]
|
0.1 -0.4V(1) | |||||
|
||||||