LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Nissan-Datsun >> 2003 >> Sentra SE-R, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 1305 (Power Window System) >> Power Window System >> Trouble Diagnoses Symptom Chart/Crew Cab
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Trouble Diagnoses Symptom Chart/Crew Cab

WARNING: This page is about a different car, the 2004 Nissan Titan. However, it is still accessible from the selected car via links, so may be relevant.
TROUBLE DIAGNOSES SYMPTOM

Symptom Repair order
None of the power windows can be operated using any switch 1. BCM power supply and ground circuit check
2. Main power window and door lock/unlock power supply and ground circuit check
3. Power window serial link check
4. Replace BCM
Front power window LH alone does not operate 1. Front power window motor LH circuit check
2. Replace main power window and door lock/ unlock switch
Front power window RH alone does not operate 1. Power window and door lock/unlock switch RH power supply and ground circuit check
2. Power window serial link check
3. Front power window motor RH circuit check
4. Replace BCM
Rear power window LH alone does not operate 1. Rear power window motor LH circuit check
Rear power window RH alone does not operate 1. Rear power window motor RH circuit check
Anti-pinch system does not operate normally (Front LH) 1. Door window sliding part malfunction
  • A foreign material adheres to window glass or glass run rubber.
  • Glass run rubber wear or deformation.
  • Sash is tilted too much, or not enough.
2. Limit switch adjusting
3. Limit switch circuit check LH
4. Encoder circuit check LH
Anti-pinch system does not operate normally (Front RH) 1. Door window sliding part malfunction
  • A foreign material adheres to window glass or glass run rubber.
  • Glass run rubber wear or deformation.
  • Sash is tilted too much, or not enough.
2. Limit switch adjusting
3. Limit switch circuit check RH
4. Encoder circuit check RH
Power window retained power operation does not operate properly 1. Check the retained power operation mode setting.
2. Door switch check
3. Replace BCM.
Does not operate by key cylinder switch LH 1. Door key cylinder switch LH check
2. Replace main power window and door lock/ unlock switch
Power window lock switch does not function 1. Power window lock switch circuit check