With CONSULT-II
- Turn ignition switch ON.
- Start engine and warm it up to normal operating temperature.
If engine cannot be started, go to "DIAGNOSTIC PROCEDURE ".
- Select "DATA MONITOR" mode with CONSULT-II.
- Check the voltage of "MAS A/F SE-B1" with "DATA MONITOR".
- Increases engine speed to about 4, 000 RPM.
- Monitor the linear voltage rise in response to engine speed increases.
If NG, go to "DIAGNOSTIC PROCEDURE ".
If OK, go to following step.
- Maintain the following conditions for at least 10 consecutive seconds.TESTING CONDITION DESCRIPTION