With Consult-II
- Turn ignition switch ON.
- Select "DATA MONITOR" mode with CONSULT-II.
- Wait at least 10 seconds.
- Press CRUISE switch for at least 10 seconds, then release it and wait at least 10 seconds.
- Press RESUME/ACCEL switch for at least 10 seconds, then release it and wait at least 10 seconds.
- Press SET/COAST switch for at least 10 seconds, then release it and wait at least 10 seconds.
- Press CANCEL switch for at least 10 seconds, then release it and wait at least 10 seconds.
- If DTC is detected, go to
"DIAGNOSTIC PROCEDURE ".