Diagnostic Procedure
- CHECK STARTING SYSTEM
Does the engine turn over?
(Does the starter motor operate?)
Yes or No
- Yes: GO TO 2.
- No: Check starting system. Refer to STARTERS .
- RETIGHTEN GROUND SCREWS
- Turn ignition switch OFF.
- Loosen and retighten engine ground screws.
- GO TO 3.
- CHECK POWER SUPPLY
- Disconnect camshaft position (CMP) sensor harness connector.
- Turn ignition switch ON.
- Check voltage between terminal 5 and ground with CONSULT-II or tester.
Voltage : Battery voltage
OK or NG
- OK: GO TO 5.
- NG: GO TO 4.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness for open or short between camshaft position sensor and ECM relay
- Harness for open or short between camshaft position sensor and ECM
- Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK INPUT SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check harness continuity between CMP sensor terminal 4 and ECM terminal 49, CMP sensor terminal 3 and ECM terminals 44, 48.
Refer to WIRING DIAGRAM .
Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
- OK: GO TO 6.
- NG: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK GROUND CIRCUIT
- Check harness continuity between CMP sensor terminal 6 and engine ground.
Refer to WIRING DIAGRAM .
Continuity should exist.
- Also check harness for short to power.
OK or NG
- OK: GO TO 7.
- NG: Repair open circuit or short to power in harness or connectors.
- Check harness continuity between CMP sensor terminal 6 and engine ground.
- CHECK CAMSHAFT POSITION SENSOR
Refer to COMPONENT INSPECTION .
OK or NG
- OK: GO TO 8.
- NG: Replace camshaft position sensor.
- CHECK INTERMITTENT INCIDENT
Perform TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT .
- : INSPECTION END.