Diagnostic Procedure
- CHECK SWIRL CONTROL VALVE POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect swirl control valve harness connector.
- Turn ignition switch ON.
- Check voltage between swirl control valve terminals 2, 5 and ground with CONSULT-II or tester.
- Voltage: Battery voltage
OK or NG
- OK: GO TO 3.
- NG: GO TO 2.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness for open or short between swirl control valve and ECM relay
- Repair open circuit or short to ground or short to power in harness or connectors.
- Harness for open or short between swirl control valve and ECM relay
- CHECK SWIRL CONTROL VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check harness continuity between ECM terminals and swirl control valve terminals as follows.
Refer to WIRING DIAGRAM .
Courtesy of NISSAN MOTOR CO., U.S.A.
- Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
- OK: GO TO 4.
- NG: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK SWIRL CONTROL VALVE
Check resistance between swirl control valve terminal 2 and terminal 1, 3, terminal 5 and terminals 4, 6.
- Resistance: 20.5 - 23.5 Ω [at 20°C (68°F)]
OK or NG
- OK: GO TO 5.
- NG: Replace intake manifold collector assembly.
- RETIGHTEN GROUND SCREWS
Loosen and retighten engine ground screws.
- GO TO 6.
- CHECK SWIRL CONTROL VALVE POSITION SENSOR POWER SUPPLY CIRCUIT
- Disconnect swirl control valve position sensor harness connector.
- Turn ignition switch ON.
- Check voltage between swirl control valve position sensor terminal 3 and ground with CONSULT-II or tester.
- Voltage: Approximately 5V
OK or NG
- OK: GO TO 7.
- NG: Repair open circuit or short to ground or short to power in harness connectors.
- CHECK SWIRL CONTROL VALVE POSITION SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Disconnect TCM harness connector.
- Check harness continuity between swirl control valve position sensor terminal 1 and ECM terminal 67, TCM terminal 42.
Refer to WIRING DIAGRAM .
- Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
- OK: GO TO 3.
- NG: GO TO 8.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness for open or short between swirl control valve position sensor and TCM
- Harness for open or short between swirl control valve position sensor and ECM
- Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK SWIRL CONTROL VALVE POSITION SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check harness continuity between ECM terminal 54 and swirl control valve position sensor terminal 2.
Refer to WIRING DIAGRAM .
- Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
- OK (With CONSULT-II): GO TO 10.
- NG: Repair open circuit or short to ground or short to power in harness or connectors.
- Check harness continuity between ECM terminal 54 and swirl control valve position sensor terminal 2.
- CHECK INTERMITTENT INCIDENT
Refer to TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT .
OK or NG
- OK: Replace intake manifold assembly.
- NG: Repair or replace.