Diagnostic Procedure (M45)
WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2003 Infiniti QX4, 2003 Infiniti Q45, 2003 Infiniti M45, 2003 Infiniti I35, and 2003 Infiniti G35. However, it is still accessible from the selected car via links, so may be relevant.
- Start engine and warm to normal operating temperature. Turn A/C switch and blower switch to ON position. Measure voltage between ground and ECM terminal No. 88 (Pink wire) by backprobing. See. Voltage should be 1-4 volts. If voltage is as specified, system is okay. If voltage is not as specified, go to next step.
- Turn A/C switch and blower switch to OFF position. Turn ignition switch to OFF position. Disconnect refrigerant pressure sensor harness connector located in front of condenser. Turn ignition switch to ON position. Measure voltage between ground and refrigerant pressure sensor harness connector terminal No. 1 (Blue wire). If voltage is about 5 volts, go to step 4. If voltage is not about 5 volts, go to next step.
- Check the following:
- Check for open or short between refrigerant pressure sensor and ECM.
- Check for poor connections at ECM and refrigerant pressure sensor harness connectors.
Repair as necessary.
- Turn ignition switch to OFF position. Check continuity between engine ground and refrigerant pressure sensor harness connector terminal No. 3 (Black wire). Continuity should exist. Also, check circuit for short to voltage. If problem is found, go to next step. If circuit is okay, go to step 6.
- Check the following:
- Check for poor connections at ECM and refrigerant pressure sensor harness connectors.
- Check joint connector-30.
- Check for open or short between refrigerant pressure sensor and ECM.
Repair as necessary. See ENGINE PERFORMANCE and AIR CONDITIONING in SYSTEM WIRING DIAGRAMS article in ELECTRICAL.
- Disconnect ECM harness connector. Check continuity between refrigerant pressure sensor harness connector terminal No. 2 (Pink wire) and ECM harness connector terminal No. 88 (Pink wire). Continuity should exist. Also, check circuit for short to ground and short to voltage. If problem is found, go to next step. If circuit is okay, go to step 8.
- Check the following:
- Check for poor connection at ECM and refrigerant pressure sensor harness connectors.
- Check for open or short between refrigerant pressure sensor and ECM.
Repair as necessary.
- No problem is indicated at this time. Check for intermittent condition. See INTERMITTENTS in TROUBLE SHOOTING - NO CODES article. If problem is found, repair as necessary. If problem is not found, replace refrigerant pressure sensor.