  1. After turning ignition switch OFF, connect CONSULT-II and CONVERTER to data link connector.
    CAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which performs CAN communication.
  2. Turn ignition switch ON.
  3. Touch "START (NISSAN BASED VHCL)", "ABS", "DATA MONITOR" in order on the CONSULT-II screen. If "ABS" is not indicated, go to "CONSULT-II DATA LINK CONNECTOR (DLC) CIRCUIT ".
    CAUTION: When "START (NISSAN BASED VHCL)" is touched immediately after starting engine or turning on ignition switch, "ABS" might not be displayed in the system selection screen. In this case, repeat the operation from step 1.
  4. Return to the Monitor Item Selection screen, and touch "ECU INPUT SIGNALS", "MAIN SIGNALS" or "SELECTION FROM MENU". Refer to the following information.
  5. When "START" is touched, the data monitor screen is displayed.