Throttle Control Motor Relay
- Apply 12V direct current between relay terminals 1 and 2.
- Check continuity between relay terminals 3 and 5.
Courtesy of NISSAN MOTOR CO., U.S.A.
THROTTLE CONTROL MOTOR RELAY TERMINALS 3 & 5 CONTINUITYConditions Continuity 12V direct current supply between terminals 1 and 2 Yes No current supply No - If NG, replace throttle control motor relay.