GENERATOR SPECIFICATIONS

Application QG18DE QR25DE
Type LR180-769 LR1100-734
HITACHI
Nominal rating 12V-80A 12V-110A
Ground polarity Negative
Minimum revolution under no-load (When 13.5 volts is applied) 1, 000 RPM 950 RPM
Hot output current (When 13.5 volts is applied) 23A/1, 300 RPM
66A/2, 500 RPM
79A/5, 000 RPM
35A/1, 300 RPM
83A/2, 500 RPM
95A/5, 000 RPM
Regulated output voltage 14.1 - 14.7V
Minimum length of brush 6 mm (0.236 in)
Brush spring pressure 1.000 - 3.432 N (0.102 - 0.350 kg, 0.225 - 0.772 lbs)
Slip ring minimum outer diameter 26.0 mm (1.024 in)
Rotor (Field coil) resistance 2.67 ohms 2.31 ohms