Diagnostic Procedure
- CHECK GROUND CONNECTIONS
- Turn ignition switch OFF.
- Loosen and retighten four ground screws on the body.
Refer to "GROUND INSPECTION ."
OK or NG
OK: GO TO 2.
NG: Repair or replace ground connections.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER
- Disconnect EVAP control system pressure sensor harness connector.
- Check sensor harness connector for water.
Water should not exist .
OK or NG
OK: GO TO 3.
NG: Repair or replace harness connector.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to "COMPONENT INSPECTION ."
OK or NG
OK: GO TO 4.
NG: Replace EVAP control system pressure sensor.
- CHECK INTERMITTENT INCIDENT
Refer to "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT ."
For wiring diagram, refer to "WIRING DIAGRAM ."
>> INSPECTION END