EVAP Canister
Check EVAP canister as follows:
- Block port B .
- Blow air into port A and check that it flows freely out of port C .
- Release blocked port B .
- Apply vacuum pressure to port B and check that vacuum pressure exists at the ports A and C .
- Block port A and B .
- Apply pressure to port C and check that there is no leakage.