Water Temperature Signal Inspection
Symptom: Improper water temperature gauge indication.
- CHECK COMBINATION METER INPUT SIGNAL
- Start engine and select "METER/M&A" on CONSULT-III.
- Run the engine at different temperatures and compare water temperature with "W TEMP METER" of "DATA MONITOR". Indication should be as follows:
High: 130°C (266°F)
Normal: 70 - 105°C (158 - 221°F)
Cold: Less than 50°C (122°F)
OK or NG
OK: Perform ECM self-diagnosis. Refer to "SELF-DIAG RESULTS MODE ".
NG: Replace combination meter. Refer to "COMBINATION METER ".