Terminals and Reference Values for Double Meter
DOUBLE METER CONNECTOR TERMINAL VALUES REFERENCE
| Terminal No. | Wire color | Item | Condition | Voltage (V) (Approx.) | |
|---|---|---|---|---|---|
| Ignition switch | Operation or condition | ||||
| 1 | L | CAN-H | - | - | - |
| 2 | P | CAN-L | - | - | - |
| 3 | Y | Oil pressure sensor power supply | ON | - | 5.5 |
| 4 | G | Oil pressure sensor signal | ON | When ignition switch is in the ON position. (Engine stopped) | 0.5 |
| Engine running. [When the oil pressure is 60 psi (4.22 kg/cm2 )] | 2.5 | ||||
| 5 | R | Oil pressure sensor ground | ON | - | 0 |
| 6 | SB | Oil pressure warn out | ON | Engine oil pressure is below 4.52 psi (0.318 kg/cm2 ) | 0.5 |
| Engine oil pressure is above 6.5 psi (0.457 kg/cm2 ) | Battery voltage | ||||
| 7 | W | Battery power supply | OFF | - | Battery voltage |
| 8 | P | Ignition switch ON or START | ON | - | Battery voltage |
| 9 | B | Ground | ON | - | 0 |
| 10 | |||||
| 11 | R | Illumination control | - | - | Refer to "ILLUMINATION OPERATION BY LIGHTING SWITCH ". |
| 12 | V | Illumination control | - | - | Refer to "ILLUMINATION OPERATION BY LIGHTING SWITCH ". |