EVAP Canister
Check EVAP canister as follows:
- Block port B.
- Blow air into port A and check that it flows freely out of port C.
- Release blocked port B.
- Apply vacuum pressure to port B and check that vacuum pressure exists at the ports A and C.
- Block port A and B.
- Apply pressure to port C and check that there is no leakage.