Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection E38. Refer to "CIRCUIT INSPECTION ".
Is the inspection result normal?
YES: GO TO 2.
NO: Repair or replace ground connection.
- CHECK ECM GROUND CIRCUIT FOR OPEN AND SHORT
- Disconnect ECM harness connectors.
- Check the continuity between ECM harness connector and ground.CONTINUITY SPECIFICATION
ECM Ground Continuity Connector Terminal F7 10 Ground Existed 11 E16 108 - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 4.
NO: GO TO 3.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors F1, E8
- Harness for open or short between ECM and ground
Repair open circuit or short to power in harness or connectors.
- CHECK ECM POWER SUPPLY CIRCUIT-I
- Reconnect ECM harness connectors.
- Turn ignition switch ON.
- Check the voltage between ECM harness connector and ground.
VOLTAGE SPECIFICATIONECM Ground Voltage Connector Terminal E16 93 Ground Battery voltage Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 5.
- DETECT MALFUNCTIONING PART
Check the following.
- 15 A fuse (No. 62)
- Harness for open or short between ECM and fuse
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK ECM POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF and wait at least 10 seconds.
- Turn ignition switch ON and then OFF.
- Check the voltage between ECM harness connector and ground.
VOLTAGE SPECIFICATIONECM Ground Voltage Connector Terminal E16 105 Ground After turning ignition switch OFF, battery voltage will exist for a few seconds, then drop approximately 0 V. Is the inspection result normal?
YES: GO TO 7.
NO: GO TO 9.
- CHECK ECM POWER SUPPLY CIRCUIT-III
- Turn ignition switch ON.
- Check the voltage between IPDM E/R harness connector and ground.
VOLTAGE SPECIFICATIONIPDM E/R Ground Voltage Connector Terminal E14 44 Ground Battery voltage Is the inspection result normal?
YES: GO TO 8.
NO: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION " (WITH I-key) or "REMOVAL AND INSTALLATION " (WITHOUT I-KEY).
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END
- CHECK ECM POWER SUPPLY CIRCUIT-IV
- Turn ignition switch OFF and wait at least 10 seconds.
- Check the voltage between ECM harness connector and ground.
VOLTAGE SPECIFICATIONECM Ground Voltage Connector Terminal F7 32 Ground Battery voltage Is the inspection result normal?
YES: GO TO 13.
NO: GO TO 10.
- CHECK ECM POWER SUPPLY CIRCUIT-V
- Disconnect ECM harness connector.
- Disconnect IPDM E/R harness connector E14.
- Check the continuity between ECM harness connector and IPDM E/R harness connector.CONTINUITY SPECIFICATION
ECM IPDM E/R Continuity Connector Terminal Connector Terminal E7 32 E14 40 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 12.
NO: GO TO 11.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E8, F1
- Harness for open or short between ECM and IPDM E/R
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK FUSE
- Disconnect 20 A fuse (No. 43) from IPDM E/R.
- Check 20 A fuse.
Is the inspection result normal?
YES: GO TO 15.
NO: Replace 20 A fuse.
- CHECK ECM POWER SUPPLY CIRCUIT-VI
- Disconnect ECM harness connector.
- Disconnect IPDM E/R harness connector E14.
- Check the continuity between ECM harness connector and IPDM E/R harness connector.CONTINUITY SPECIFICATION
ECM IPDM E/R Continuity Connector Terminal Connector Terminal F16 105 E14 43 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 15.
NO: GO TO 14.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E8, F1
- Harness for open or short between ECM and IPDM E/R
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
Is the inspection result normal?
YES: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION "(WITH I-key) or "REMOVAL AND INSTALLATION "(WITHOUT I-KEY).
NO: Repair open circuit or short to ground or short to power in harness or connectors.