Diagnosis Procedure
- CHECK IGNITION COIL POWER SUPPLY CIRCUIT-I
- Turn ignition switch OFF, wait at least 10 seconds and then turn it ON.
- Check the voltage between ECM harness connector and ground.VOLTAGE SPECIFICATION
ECM Voltage Connector + - Terminal Terminal E10 105 112 Battery voltage
Is the inspection result normal?
YES: GO TO 2.
NO: Refer to "DIAGNOSIS PROCEDURE ".
- CHECK IGNITION COIL POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF.
- Disconnect condenser harness connector.
- Turn ignition switch ON.
- Check the voltage between condenser harness connector and ground.VOLTAGE SPECIFICATION
Condenser Ground Voltage Connector Terminal F26 1 Ground Battery voltage
Is the inspection result normal?
YES: GO TO 4.
NO: GO TO 3.
- CHECK IGNITION COIL POWER SUPPLY CIRCUIT-III
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector.
- Check the continuity between IPDM E/R harness connector and condenser harness connector.CONTINUITY CHART
IPDM E/R Condenser Continuity Connector Terminal Connector Terminal F10 49 F26 1 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: Refer to "DIAGNOSIS PROCEDURE ".
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK CONDENSER GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Check the continuity between condenser harness connector and ground.CONTINUITY CHART
Condenser Ground Continuity Connector Terminal F26 2 Ground Existed - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 5.
NO: Repair open circuit or short to power in harness or connectors.
- CHECK CONDENSER
Refer to "COMPONENT INSPECTION (CONDENSER) "
Is the inspection result normal?
YES: GO TO 6.
NO: Replace condenser.
- CHECK IGNITION COIL POWER SUPPLY CIRCUIT-V
- Reconnect all harness connectors disconnected.
- Disconnect ignition coil harness connector.
- Turn ignition switch ON.
- Check the voltage between ignition coil harness connector and ground.VOLTAGE SPECIFICATION
Ignition coil Ground Voltage Cylinder Connector Terminal 1 F34 3 Ground Battery voltage 2 F35 3 3 F36 3 4 F37 3 5 F38 3 6 F39 3
Is the inspection result normal?
YES: GO TO 7.
NO: Repair or replace harness or connectors.
- CHECK IGNITION COIL GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Check the continuity between ignition coil harness connector and ground.CONTINUITY CHART
Ignition coil Ground Continuity Cylinder Connector Terminal 1 F34 2 Ground Existed 2 F35 2 3 F36 2 4 F37 2 5 F38 2 6 F39 2 - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 8.
NO: Repair open circuit or short to power in harness or connectors.
- CHECK IGNITION COIL OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Disconnect ECM harness connector.
- Check the continuity between ignition coil harness connector and ECM harness connector.CONTINUITY CHART
Ignition coil ECM Continuity Cylinder Connector Terminal Connector Terminal 1 F34 1 F14 11 Existed 2 F35 1 10 3 F36 1 9 4 F37 1 21 5 F38 1 19 6 F39 1 18 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 9.
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK IGNITION COIL WITH POWER TRANSISTOR
Refer to "COMPONENT INSPECTION (IGNITION COIL WITH POWER TRANSISTOR) ".
Is the inspection result normal?
YES: GO TO 10.
NO: Replace malfunctioning ignition coil with power transistor.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
: INSPECTION END