Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn A/C switch and blower fan switch OFF.
- Stop engine.
- Turn ignition switch OFF.
- Check ground connection E9. Refer to Ground Inspection in
"CIRCUIT INSPECTION
".
Is the inspection result normal?
YES: GO TO 2.
NO: Repair or replace ground connection.
- CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY CIRCUIT
- Disconnect refrigerant pressure sensor harness connector.
- Turn ignition switch ON.
- Check the voltage between refrigerant pressure sensor harness connector and ground.VOLTAGE SPECIFICATION
Refrigerant pressure sensor Ground Voltage (V) Connector Terminal E219 1 Ground Approx. 5
Is the inspection result normal?
YES: GO TO 4.
NO: GO TO 3.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E3, F1
- Junction block connectors E44, E45
- IPDM E/R harness connectors E18, E201
- Harness for open or short between ECM and refrigerant pressure sensor
: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK REFRIGERANT PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.CONTINUITY CHART
Refrigerant pressure sensor ECM Continuity Connector Terminal Connector Terminal E219 3 F13 40 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 5.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E3, F1
- IPDM E/R harness connectors E18, E201
- Harness for open or short between ECM and refrigerant pressure sensor
: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK REFRIGERANT PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.CONTINUITY CHART
Refrigerant pressure sensor ECM Continuity Connector Terminal Connector Terminal E219 2 F13 39 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 8.
NO: GO TO 7.
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E3, F1
- IPDM E/R harness connectors E18, E201
- Harness for open or short between ECM and refrigerant pressure sensor
: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
Is the inspection result normal?
YES: Replace refrigerant pressure sensor.
NO: Repair or replace malfunctioning part.