Diagnosis Procedure
- CHECK OVERALL FUNCTION
- Turn ignition switch ON.
- Pinch fuel feed hose (1) with two fingers.
- Illustration shows the view with intake air duct removed.
Fuel pressure pulsation should be felt on the fuel feed hose for 1 second after ignition switch is turned ON .
OK or NG
OK : INSPECTION END
NG : GO TO 2.
- Illustration shows the view with intake air duct removed.
- CHECK FUEL PUMP POWER SUPPLY CIRCUIT-I
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Turn ignition switch ON.
- Check voltage between ECM terminal 23 and ground with CONSULT- III or tester.
Voltage: Battery voltage
OK or NG
OK : GO TO 5.
NG : GO TO 3.
- CHECK FUEL PUMP POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector E46.
- Turn ignition switch ON.
- Check voltage between IPDM E/R terminal 47 and ground with CONSULT-III or tester.
Voltage: Battery voltage
OK or NG
OK : GO TO 4.
NG : GO TO 11.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E8, F8
- Harness for open or short between IPDM E/R and ECM
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK FUEL PUMP POWER SUPPLY CIRCUIT-III
- Turn ignition switch OFF.
- Reconnect all harness connectors disconnected.
- Disconnect "fuel level sensor unit and fuel pump" harness connector (1).
- Illustration shows the view with inspection hole cover removed.
- Turn ignition switch ON.
- Check voltage between "fuel level sensor unit and fuel pump" terminal 1 and ground with CONSULT-III or tester.
Voltage: Battery voltage should exist for 1 second after ignition switch is turned ON .
OK or NG
OK : GO TO 9.
NG : GO TO 6.
- CHECK 15A FUSE
- Turn ignition switch OFF.
- Disconnect 15A fuse.
- Check 15A fuse.
OK or NG
OK : GO TO 7.
NG : Replace fuse.
- CHECK FUEL PUMP POWER SUPPLY CIRCUIT-IV
- Disconnect IPDM E/R harness connector E45.
- Check harness continuity between IPDM E/R terminal 36 and "fuel level sensor unit and fuel pump" terminal 1. Refer to Wiring Diagram.
Continuity should exist .
- Also check harness for short to ground and short to power.
OK or NG
OK : GO TO 13.
NG : GO TO 8.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors M69, E7
- Harness connectors M12, B101
- Harness for open or short between IPDM E/R and "fuel level sensor unit and fuel pump"
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK FUEL PUMP GROUND CIRCUIT
- Check harness continuity between "fuel level sensor unit and fuel pump" terminal 3 and ground.
Refer to Wiring Diagram.
Continuity should exist .
- Also check harness for short to power.
OK or NG
OK : GO TO 10.
NG : Repair or replace harness or connectors.
- Check harness continuity between "fuel level sensor unit and fuel pump" terminal 3 and ground.
- CHECK FUEL PUMP
Refer to "COMPONENT INSPECTION ".
OK or NG
OK : GO TO 11.
NG : Replace fuel pump.
- CHECK INTERMITTENT INCIDENT
Refer to TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT .
OK or NG
OK : Replace IPDM E/R. Refer to REMOVAL AND INSTALLATION OF IPDM E/R .
NG : Repair or replace harness or connectors.