Diagnosis Procedure
- CHECK FPCM POWER SUPPLY CIRCUIT-I
- Turn ignition switch OFF.
- Disconnect FPCM harness connector.
- Turn ignition switch ON.
- Check the voltage between FPCM harness connector and ground.TERMINAL VOLTAGE REFERENCE CHART
FPCM Ground Voltage Connector Terminal B41 10 Ground Battery voltage Is the inspection result normal?
YES: GO TO 5.
NO: GO TO 2.
- CHECK FPCM POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector.
- Check the continuity between IPDM E/R harness connector and FPCM harness connector.TERMINAL CONTINUITY REFERENCE CHART
IPDM E/R FPCM Continuity Connector Terminal Connector Terminal E10 13 B41 10 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 3.
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK FUSE
- Disconnect 15 A fuse (No. 41) from IPDM E/R.
- Check 15 A fuse.
Is the inspection result normal?
YES: GO TO 4.
NO: Replace 15 A fuse.
- CHECK INTERMITTENT INCIDENT
Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".
Is the inspection result normal?
YES: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK FPCM GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Check the continuity between FPCM harness connector and ground.TERMINAL CONTINUITY REFERENCE CHART
FPCM Ground Continuity Connector Terminal B41 5 Ground Existed - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 6.
NO: Repair open circuit or short to power in harness or connectors.
- CHECK FPCM INPUT AND OUTPUT CIRCUITS FOR OPEN AND SHORT
- Disconnect ECM harness connector.
- Check the continuity between FPCM harness connector and ECM harness connector.TERMINAL CONTINUITY REFERENCE CHART
FPCM ECM Continuity Connector Terminal Connector Terminal B41 8 F7 21 Existed 9 20 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 7.
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK FUEL PUMP CONTROL CIRCUIT FOR OPEN AND SHORT
- Disconnect "fuel level sensor unit" harness connector.
- Check the continuity between FPCM harness connector and "fuel level sensor unit" harness connector.TERMINAL CONTINUITY REFERENCE CHART
FPCM Fuel level sensor unit Continuity Connector Terminal Connector Terminal B41 6 B40 3 Existed 7 1 Is the inspection result normal?
YES: GO TO 8.
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK FUEL PUMP
Check fuel pump. Refer to "COMPONENT INSPECTION (FUEL PUMP) ".
Is the inspection result normal?
YES: GO TO 9.
NO: Replace fuel pump. Refer to "EXPLODED VIEW ".
- CHECK FPCM
Check FPCM. Refer to "COMPONENT INSPECTION (FPCM) ".
Is the inspection result normal?
YES: GO TO 10.
NO: Replace fuel pump. Refer to "EXPLODED VIEW ".
- CHECK INTERMITTENT INCIDENT
Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".
Repair or replace malfunctioning part.