Power Distribution System: Fail-safe
FAIL-SAFE CONTROL BY DTC
BCM performs fail-safe control when any DTC are detected.
FAIL-SAFE REFERENCE CHART
| Display contents of CONSULT | Fail-safe | Cancellation |
|---|---|---|
| B2192: ID DISCORD BCM-ECM | Inhibit engine cranking | Erase DTC |
| B2193: CHAIN OF BCM-ECM | Inhibit engine cranking | Erase DTC |
| B2195: ANTI-SCANNING | Inhibit engine cranking | Ignition switch ON → OFF |
| B2196: DONGLE NG | Inhibit engine cranking | Erase DTC |
| B2198: NATS ANTENNA AMP | Inhibit engine cranking | Erase DTC |
| B2608: STARTER RELAY | Inhibit engine cranking | 500 ms after the following signal communication status becomes consistent
|
| B260F: ENG STATE SIG LOST | Inhibit engine cranking | When any of the following conditions are fulfilled
|
| B26F1: IGN RELAY OFF | Inhibit engine cranking | When the following conditions are fulfilled
|
| B26F2: IGN RELAY ON | Inhibit engine cranking | When the following conditions are fulfilled
|
| B26F3: START CONT RLY ON | Inhibit engine cranking | When the following conditions are fulfilled
|
| B26F4: START CONT RLY OFF | Inhibit engine cranking | When the following conditions are fulfilled
|
| B26F7: BCM | Inhibit engine cranking by Intelligent Key system | When room antenna and luggage room antenna functions normally |
REAR WIPER MOTOR PROTECTION
BCM detects the rear wiper stopping position according to the rear wiper stop position signal.
When the rear wiper stop position signal does not change for more than 5 seconds while driving the rear wiper, BCM stops power supply to protect the rear wiper motor.
Condition of cancellation
- More than 1 minute is passed after the rear wiper stop.
- Turn rear wiper switch OFF.
- Operate the rear wiper switch or rear washer switch.
FAIL-SAFE CONTROL OF COMBINATION SWITCH READING FUNCTION CAUSED BY LOW POWER SUPPLY VOLTAGE
If voltage of battery power supply lower, BCM maintains combination switch reading to the status when input voltage is less than approximately 9 V.
NOTE:
When voltage of battery power supply is approximately 9 V or more, combination switch reading function returns to normal operation.