Diagnosis Procedure
- CHECK COOLING FAN RELAY POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect cooling fan relays-2, -3.
- Turn ignition switch ON.
- Check the voltage between cooling fan relays-2, -3 harness connectors and ground.TERMINAL VOLTAGE REFERENCE CHART
Cooling fan relay Ground Voltage Connector Terminal E57 (cooling fan relay-2) 2 Ground Battery voltage 5 E59 (cooling fan relay-3) 2 5 Is the inspection result normal?
YES: GO TO 2.
NO: Perform the trouble diagnosis for power supply circuit.
- CHECK COOLING FAN RELAY OUTPUT SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connectors.
- Check the continuity between cooling fan relay-2, -3 harness connectors and IPDM E/R harness connector.TERMINAL CONTINUITY REFERENCE CHART
Cooling fan relay IPDM E/R Continuity Connector Terminal Connector Terminal E57 (cooling fan relay-2) 1 E11 42 Existed E59 (cooling fan relay-3) 1 E10 34 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 3.
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK COOLING FAN MOTOR POWER SUPPLY
- Disconnect cooling fan motor-1 harness connector.
- Check the voltage between cooling fan motor-1 harness connector and ground.TERMINAL VOLTAGE REFERENCE CHART
Cooling fan motor-1 Ground Voltage Connector Terminal E301 1 Ground Battery voltage 2 Is the inspection result normal?
YES: GO TO 4.
NO: Perform the trouble diagnosis for power supply circuit.
- CHECK COOLING FAN MOTOR CIRCUIT-I
- Disconnect cooling fan motor-2 harness connector.
- Check the continuity between cooling fan relay-2, -3 harness connectors and cooling fan motor-1, -2 harness connectors.TERMINAL CONTINUITY REFERENCE CHART
Cooling fan relay Cooling fan motor Continuity Connector Terminal Connector Terminal E57 (cooling fan relay-2) 3 E302 (Cooling fan motor-2) 2 Existed 7 E301 (Cooling fan motor-1) 3 E59 (cooling fan relay-3) 3 E302 (Cooling fan motor-2) 1 7 E301 (Cooling fan motor-1) 4 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 5.
NO: Perform the trouble diagnosis for power supply circuit.
- CHECK COOLING FAN MOTOR CIRCUIT-II
- Check the continuity between IPDM E/R harness connector and cooling fan motor-1, -2 harness connector.TERMINAL CONTINUITY REFERENCE CHART
IPDM E/R Cooling fan motor Continuity Connector Terminal Connector Terminal E10 35 E301 (Cooling fan motor-1) 4 Existed 38 E302 (Cooling fan motor-2) 1 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 6.
NO: Perform the trouble diagnosis for power supply circuit.
- Check the continuity between IPDM E/R harness connector and cooling fan motor-1, -2 harness connector.
- CHECK COOLING FAN MOTOR CIRCUIT-III
- Check the continuity between cooling fan relay-2, -3 harness connectors and ground.TERMINAL CONTINUITY REFERENCE CHART
Cooling fan motor Ground Continuity Connector Terminal E57 (cooling fan relay-2) 6 Ground Existed E59 (cooling fan relay-3) 6 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 7.
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- Check the continuity between cooling fan relay-2, -3 harness connectors and ground.
- CHECK COOLING FAN MOTOR CIRCUIT-IV
- Check the continuity between cooling fan motor-2 harness connector and ground.TERMINAL CONTINUITY REFERENCE CHART
Cooling fan motor-2 Ground Continuity Connector Terminal E302 3 Ground Existed 4 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 8.
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- Check the continuity between cooling fan motor-2 harness connector and ground.
- CHECK COOLING FAN RELAYS-2 AND -3
Check cooling fan relays-2 and -3. Refer to "COMPONENT INSPECTION (COOLING FAN RELAY) ".
Is the inspection result normal?
YES: GO TO 9.
NO: Replace malfunctioning cooling fan relay.
- CHECK COOLING FAN MOTORS-1 AND -2
Check cooling fan motors-1 and -2. Refer to "COMPONENT INSPECTION (COOLING FAN MOTOR) ".
Is the inspection result normal?
YES: GO TO 10.
NO: Replace malfunctioning cooling fan motor. Refer to "EXPLODED VIEW ".
- CHECK INTERMITTENT INCIDENT
Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".
Is the inspection result normal?
YES: Replace IPDM E/R. Refer to "EXPLODED VIEW ".
NO: Repair or replace error-detected parts.