Door Switch Check
- CHECK DOOR SWITCHES INPUT SIGNAL
With CONSULT
Check door switches ("DOOR SW-DR", "DOOR SW-AS", "DOOR SW-RL", "DOOR SW-RR") in DATA MONITOR mode with CONSULT. Refer to , "CONSULT FUNCTION (BCM) ".
- When any doors are open:
DOOR SW-DR: ON
DOOR SW-AS: ON
DOOR SW-RL: ON
DOOR SW-RR: ON
- When any doors are closed:
DOOR SW-DR: OFF
DOOR SW-AS: OFF
DOOR SW-RL: OFF
DOOR SW-RR: OFF
Without CONSULT
Check voltage between BCM connector M18 or M19 terminals 12, 13, 47, 48 and ground.
Connector Item Terminals Condition Voltage (V) (Approx.) (+) (-) M19 Front door switch LH 47 Ground Open
↓
Closed0
↓
Battery voltageRear door switch LH 48 M18 Front door switch RH 12 Rear door switch RH 13 OK or NG
OK: Door switch circuit is OK.
NG: GO TO 2.
- When any doors are open:
- CHECK DOOR SWITCH CIRCUIT
- Turn ignition switch OFF.
- Disconnect door switch and BCM.
- Check continuity between door switch connector B21 (Front LH), B28 (Front RH), B26 (Rear LH), B41 (Rear RH) terminal 2 and BCM connector M18, M19 terminals 12, 13, 47 and 48.
2 - 47: Continuity should exist .
2 - 12: Continuity should exist .
2 - 48: Continuity should exist .
2 - 13: Continuity should exist .
- Check continuity between door switch connector B21 (Front LH), B28 (Front RH), B26 (Rear LH), B41 (Rear RH) terminal 2 and ground.
2 - Ground: Continuity should not exist .
OK or NG
OK: GO TO 3.
NG: Repair or replace harness.
- CHECK DOOR SWITCHES
Check continuity between door switch terminals.
Door switch (front or rear) Terminals Condition Continuity 2 - Ground Pressed No Released Yes OK or NG
OK: GO TO 4.
NG: Replace door switch.
- CHECK BCM OUTPUT VOLTAGE
- Reconnect BCM connectors.
- Check voltage between BCM connector M18, M19 terminals 12, 13, 47, 48 and ground.
12 - Ground: Battery voltage
13 - Ground: Battery voltage
47 - Ground: Battery voltage
48 - Ground: Battery voltage
OK or NG
OK: Door switch circuit is OK.
NG: Replace BCM. Refer to , "REMOVAL AND INSTALLATION OF BCM ".