Trunk Room Lamp Switch Check
- CHECK TRUNK ROOM LAMP SWITCH INPUT SIGNAL
With CONSULT
Check ("TRUNK SW") in "DATA MONITOR" mode with CONSULT.
Monitor item Trunk condition TRUNK SW OPEN : ON CLOSED : OFF Without CONSULT
- CHECK TRUNK ROOM LAMP SWITCH
- CHECK TRUNK ROOM LAMP SWITCH CIRCUIT
- Disconnect BCM connector M19.
- Check continuity between BCM harness connector M19 (A) terminal 42 and trunk room lamp switch harness connector B57 (B) terminal 1.
42 - 1: Continuity should exist .
- Check continuity between BCM harness connector M19 (A) terminal 42 and ground.
42 - Ground: Continuity should not exist .
OK or NG
OK: GO TO 4.
NG: Repair or replace harness between BCM and trunk room lamp switch.
- CHECK TRUNK ROOM LAMP SWITCH GROUND CIRCUIT
Check continuity between trunk room lamp switch harness connector B57 terminal 2 and ground.
2 - Ground: Continuity should exist .
OK or NG
OK: Check connection of harness and connector.
NG: Repair or replace trunk room lamp switch ground circuit.