Door Mirror Defogger Circuit Inspection
- CHECK FUSE
Check if the following fuse in the fuse block (J/B) is blown.
Component Parts Ampere Fuse No. Fuse block (J/B) 10A 8 OK or NG
OK: GO TO 2.
NG: If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse.
- CHECK HEATED MIRROR RELAY POWER SUPPLY CIRCUIT
- CHECK HEATED MIRROR RELAY GROUND CIRCUIT
- Turn ignition switch OFF.
- Check continuity between heated mirror relay connector E56 terminal 2 and ground.
2 - Ground: Continuity should exist .
OK or NG
OK: GO TO 4.
NG: Repair or replace harness.
- CHECKING HEATED MIRROR RELAY
Check continuity between heated mirror relay terminals 3 and 5.
Condition Continuity 12V direct current supply between terminals 1 and 2 Yes No current supply No OK or NG
OK: GO TO 5.
NG: Replace heated mirror relay.
- CHECK HARNESS CONTINUITY
- Disconnect door mirror (LH or RH).
- Check continuity between door mirror LH or RH connector (A) and heated mirror relay connector (B).
Connector Terminal Connector Terminal Continuity A B D7 (LH) 1 E56 5 Yes D106 (RH) - Check continuity between door mirror LH or RH connector (A) and ground.
A Ground Continuity Connector Terminal D7 (LH) 1 No D106 (RH) OK or NG
OK: GO TO 6.
NG: Repair or replace harness.
- CHECK GROUND CIRCUIT
Check continuity between door mirror LH or RH connector and ground.
Connector Terminals Continuity D7 (LH) 2 Ground Battery voltage D106 (RH) OK or NG
OK: Replace door mirror (LH or RH). Refer to , "REMOVAL AND INSTALLATION ".
NG: Repair or replace harness.