Diagnosis Procedure
- CHECK IGNITION COIL POWER SUPPLY CIRCUIT-I
- Turn ignition switch OFF, wait at least 10 seconds and then turn ON.
- Check the voltage between ECM harness connector and ground.
ECM Voltage Connector Terminal + - E16 105 108 Battery voltage Is the inspection result normal?
YES: GO TO 2.
NO: Go to "DIAGNOSIS PROCEDURE ".
- CHECK IGNITION COIL POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF.
- Disconnect condenser harness connector.
- Turn ignition switch ON.
- Check the voltage between condenser harness connector and ground.
Condenser Ground Voltage Connector Terminal F26 1 Ground Battery voltage Is the inspection result normal?
YES: GO TO 5.
NO: GO TO 3.
- CHECK IGNITION COIL POWER SUPPLY CIRCUIT-III
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector F42.
- Check the continuity between IPDM E/R harness connector and condenser harness connector.
IPDM E/R Condenser Continuity Connector Terminal Connector Terminal F42 34 F26 1 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 11.
NO: GO TO 4.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness for open or short between IPDM E/R and condenser
: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK CONDENSER GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Check the continuity between condenser harness connector and ground.
Condenser Ground Continuity Connector Terminal F26 2 Ground Existed - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 6.
NO: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK CONDENSER
Refer to "COMPONENT INSPECTION (CONDENSER) "
Is the inspection result normal?
YES: GO TO 7.
NO: Replace condenser.
- CHECK IGNITION COIL POWER SUPPLY CIRCUIT-IV
- Reconnect all harness connectors disconnected.
- Disconnect ignition coil harness connector.
- Turn ignition switch ON.
- Check the voltage between ignition coil harness connector and ground.
Ignition coil Ground Voltage Cylinder Connector Terminal 1 F34 3 Ground Battery voltage 2 F35 3 3 F36 3 4 F37 3 Is the inspection result normal?
YES: GO TO 8.
NO: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK IGNITION COIL GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Check the continuity between ignition coil harness connector and ground.
Ignition coil Ground Continuity Cylinder Connector Terminal 1 F34 2 Ground Existed 2 F35 2 3 F36 2 4 F37 2 - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 9.
NO: Repair open circuit or short to power in harness or connectors.
- CHECK IGNITION COIL OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Disconnect ECM harness connector.
- Check the continuity between ECM harness connector and ignition coil harness connector.
Ignition coil ECM Continuity Cylinder Connector Terminal Connector Terminal 1 F34 1 F10 17 Existed 2 F35 1 18 3 F36 1 22 4 F37 1 21 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 10.
NO: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK IGNITION COIL WITH POWER TRANSISTOR
Refer to "COMPONENT INSPECTION (IGNITION COIL WITH POWER TRANSISTOR) ".
Is the inspection result normal?
YES: GO TO 11.
NO: Replace malfunctioning ignition coil with power transistor. Refer to "REMOVAL AND INSTALLATION ".
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
: INSPECTION END