Diagnosis Procedure
- CHECK BCM POWER SUPPLY AND GROUND CIRCUIT
Check BCM power supply and ground circuit.
Refer to "DIAGNOSIS PROCEDURE " (with Intelligent Key) or "DIAGNOSIS PROCEDURE " (without Intelligent Key).
Is the inspection result normal?
YES: GO TO 2.
NO: Repair or replace the malfunctioning parts.
- CHECK POWER WINDOW MAIN SWITCH POWER SUPPLY AND GROUND CIRCUIT
Check power window main switch power supply and ground circuit.
Refer to "POWER WINDOW MAIN SWITCH: DIAGNOSIS PROCEDURE ".
Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace the malfunctioning parts.
- REPLACE POWER WINDOW MAIN SWITCH
- Replace power window main switch.
- Confirm the operation after replacement.
Is the result normal?
YES: INSPECTION END
NO: Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".