Encoder Circuit Check
- CHECK ENCODER OPERATION
- Turn ignition switch ON.
- Check signal between main power window and door lock/unlock switch harness connector and ground with oscilloscope.
(+) (-) Signal (Reference value) Main power window and door lock/unlock switch Connector Terminal D6 4 Ground Refer to following signal 5 Is the inspection result normal?
YES: GO TO 7.
NO: GO TO 2.
- CHECK ENCORDER SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect main power window and door lock/unlock switch connector and front power window motor LH connector.
- Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.
Main power window and door lock/unlock switch Front power window motor LH Continuity Connector Terminal Connector Terminal D6 4 D10 4 Yes 5 5 - Check continuity between main power window and door lock/unlock switch harness connector and ground.
Main power window and door lock/unlock switch Ground Continuity Connector Terminal D6 4 No 5 Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace harness.
- CHECK ENCORDER POWER SUPPLY CIRCUIT
- Connect main power window and door lock/unlock switch connector.
- Turn ignition switch ON.
- Check voltage between front power window motor LH harness connector and ground.
(+) (-) Voltage (Approx.) Front power window motor LH Connector Terminal D10 2 Ground Battery voltage Is the inspection result normal?
YES: GO TO 4.
NO: GO TO 5.
- CHECK GROUND CIRCUIT
- CHECK HARNESS CONTINUITY 1
- Turn ignition switch OFF.
- Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.
Main power window and door lock/unlock switch Front power window motor LH Continuity Connector Terminal Connector Terminal D6 12 D10 6 Yes - Check continuity between main power window and door lock/unlock switch harness connector and ground.
Main power window and door lock/unlock switch Ground Continuity Connector Terminal D6 12 No Is the inspection result normal?
YES: Replace main power window and door lock/unlock switch. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.
- CHECK HARNESS CONTINUITY 2
- Disconnect main power window and door lock/unlock switch connector.
- Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.
Main power window and door lock/unlock switch Front power window motor LH Continuity Connector Terminal Connector Terminal D6 14 D10 2 Yes Is the inspection result normal?
YES: Replace main power window and door lock/unlock switch. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
: Inspection End.