Component Function Check
- CHECK POWER WINDOW RELAY POWER SUPPLY CIRCUIT
Check that an operation noise of power window relay [located behind the A/C switch assembly (automatic A/C) or Front air control (manual A/C)] can be heard when turning the main power window and door lock/unlock switch ON.
Is the inspection result normal?
YES: Power window relay power supply circuit is OK.
NO: Refer to "DIAGNOSIS PROCEDURE ".