Component Inspection
- CHECK VDC OFF SWITCH
- Turn ignition switch OFF.
- Disconnect VDC OFF switch connector.
- Check continuity between terminals of VDC OFF switch connector.
VDC OFF switch terminals Condition Continuity 6 - 8 VDC OFF switch pressed Yes VDC OFF switch released No Is the inspection result normal?
YES: Inspection End.
NO: Replace VDC OFF switch. Refer to "REMOVAL AND INSTALLATION ".