Component Inspection
- CHECK FRONT POWER WINDOW SWITCH RH
- Turn ignition switch OFF.
- Disconnect front power window switch RH connector.
- Check front power window switch RH terminals under the following conditions.
Front power window switch RH Condition Continuity Terminal 8 7 UP Yes 12 6 11 7 NEUTRAL 12 6 11 7 DOWN 8 6 Is the inspection result normal?
YES: Inspection End.
NO: Replace front power window switch RH. Refer to "REMOVAL AND INSTALLATION ".