Encoder Circuit Check
- CHECK ENCODER OPERATION
- Turn ignition switch ON.
- Check signal between main power window and door lock/unlock switch connector D7 and ground with oscilloscope.
Terminals Signal
(Reference value)(+) (-) Main power window and door lock/unlock switch connector Terminal D7 4 Ground Refer to following signal 5
Is the inspection result normal?
YES Check intermittent incident. Refer to INTERMITTENT INCIDENT .
NO GO TO STEP 2.
- CHECK FRONT POWER WINDOW MOTOR LH POWER SUPPLY
- Turn ignition switch ON.
- Check voltage between front power window motor LH connector D9 and ground.
Terminal Voltage
(Approx.)(+) (-) Front power window motor LH connector Terminal D9 2 Ground 10
Is the measurement value within the specification?
YES: GO TO 4.
NO: GO TO 3.
- CHECK HARNESS CONTINUITY 1
- Turn ignition switch OFF.
- Disconnect main power window and door lock/unlock switch and front power window motor LH.
- Check continuity between main power window and door lock/unlock switch connector D7 and front power window motor LH connector D9.
Main power window and door lock/unlock switch connector Terminal Front power window motor LH connector Terminal Continuity D7 14 D9 2 Yes - Check continuity between main power window and door lock/unlock switch connector D7 and ground.
Main power window and door lock/unlock switch connector Terminal Ground Continuity D7 14 No
Is the inspection result normal?
YES Replace main power window and door lock/unlock switch. Refer to REMOVAL AND INSTALLATION . After that, refer to ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT SPECIAL REPAIR REQUIREMENT .
NO Repair or replace the harness or connectors.
- CHECK GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect front power window motor LH.
- Check continuity between front power window motor LH connector D9 and ground.
Front power window motor LH connector Terminal Ground Continuity D9 4 Yes
Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 5.
- CHECK HARNESS CONTINUITY 2
- Disconnect main power window and door lock/unlock switch.
- Check continuity between main power window and door lock/unlock switch connector D7 and front power window motor LH connector D9.
Main power window and door lock/unlock switch connector Terminal Front power window motor LH connector Terminal Continuity D7 12 D9 4 Yes
Is the inspection result normal?
YES Replace main power window and door lock/unlock switch. Refer to REMOVAL AND INSTALLATION . After that, refer to ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT SPECIAL REPAIR REQUIREMENT .
NO Repair or replace the harness or connectors.
- CHECK HARNESS CONTINUITY 3
- Disconnect main power window and door lock/unlock switch.
- Check continuity between main power window and door lock/unlock switch connector D7 and front power window motor LH connector D9.
Main power window and door lock/unlock switch connector Terminal Front power window motor LH connector Terminal Continuity D7 5 D9 5 Yes 4 6 - Check continuity between main power window and door lock/unlock switch connector D7 and ground.
Main power window and door lock/unlock switch connector Terminal Ground Continuity D7 5 No 4
Is the inspection result normal?
YES Replace front power window motor LH. Refer to REMOVAL AND INSTALLATION - FRONT REGULATOR . After that, refer to ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT SPECIAL REPAIR REQUIREMENT .
NO Repair or replace the harness or connectors.