| DTC | Display item | Malfunction detected condition | Possible cause |
|---|---|---|---|
| C160A | HEAT PROTECTION | When the steering wheel is operated excessively and the interior temperature of the power steering system reaches 118°C (244.4°F) or more. (Protection function)
NOTE:
Although the hydraulic pump electric power steering system warning lamp turns ON, this is not a system malfunction. The state returns to normal after stopping steering operation and waiting until the system interior temperature drops to 90°C (194°F) or less. |