Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK ENCODER SIGNAL
- Turn ignition switch ON.
- Check signal between main power window and door lock/unlock switch harness connector and ground with oscilloscope.
Signal name (+) (-) Signal
(Reference value)Main power window and door lock/unlock switch Connector Terminal Encoder signal 1 D7 5 Ground Refer to following signals Encoder signal 2 4
Is the inspection result normal?
YES
Replace main power window and door lock/unlock switch. Refer to REMOVAL AND INSTALLATION .
NO
GO TO STEP 2 .
- CHECK ENCODER SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect main power window and door lock/unlock switch connector and front power window motor LH connector.
- Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.
Main power window and door lock/unlock switch Front power window motor LH Continuity Connector Terminal Connector Terminal D7 4 D9 5 Yes 5 3 - Check continuity between main power window and door lock/unlock switch harness connector and ground.
Main power window and door lock/unlock switch Ground Continuity Connector Terminal D7 4 No 5
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Repair or replace harness.
- CHECK ENCODER POWER SUPPLY
- Connect main power window and door lock/unlock switch connector.
- Turn ignition switch ON.
- Check voltage between front power window motor LH harness connector and ground.
(+) (-) Voltage
(Approx.)Front power window motor LH Connector Terminal D9 4 Ground Battery voltage
Is the inspection result normal?
YES
GO TO STEP 5 .
NO
GO TO STEP 4 .
- CHECK ENCODER POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect main power window and door lock/unlock switch connector.
- Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.
Main power window and door lock/unlock switch Front power window motor LH Continuity Connector Terminal Connector Terminal D7 14 D9 4 Yes - Check continuity between main power window and door lock/unlock switch harness connector and ground.
Main power window and door lock/unlock switch Ground Continuity Connector Terminal D7 14 No
Is the inspection result normal?
YES
Replace main power window and door lock/unlock switch. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.
- CHECK GROUND CIRCUIT 1
- Turn ignition switch OFF.
- Check continuity between front power window motor LH harness connector and ground.
Front power window motor LH Ground Continuity Connector Terminal D9 6 Yes
Is the inspection result normal?
YES
Replace front power window motor LH. Refer to REMOVAL AND INSTALLATION .
NO
GO TO STEP 6 .
- CHECK GROUND CIRCUIT 2
- Disconnect main power window and door lock/unlock switch connector.
- Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.
Main power window and door lock/unlock switch Front power window motor LH Continuity Connector Terminal Connector Terminal D7 12 D9 6 Yes - Check continuity between main power window and door lock/unlock switch harness connector and ground.
Main power window and door lock/unlock switch Ground Continuity Connector Terminal D7 12 No
Is the inspection result normal?
YES
Replace main power window and door lock/unlock switch. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.