Component Inspection
- CHECK DOOR SWITCH
- Turn ignition switch OFF.
- Disconnect malfunctioning door switch connector.
- Check continuity between door switch terminals.
Door switch Condition Continuity Terminal Front door switch LH 3 Ground part of door switch Door switch Pressed No Released Yes Front door switch RH Pressed No Released Yes
Is the inspection result normal?
YES
Inspection End.
NO
Replace malfunction door switch. Refer to REMOVAL AND INSTALLATION .