Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK FRONT POWER WINDOW MOTOR LH INPUT SIGNAL
- Turn ignition switch OFF.
- Disconnect front power window motor LH connector.
- Turn ignition switch ON.
- Check voltage between front power window motor LH harness connector and ground.
(+) (-) Condition Voltage (V)
(Approx.)Front power window motor LH Connector Terminal D9 1 Ground Main power window and door lock/unlock switch NEUTRAL 0 DOWN Battery voltage 2 NEUTRAL 0 UP Battery voltage Is the inspection result normal?
YES
Replace front power window motor LH.
NO
GO TO STEP 2 .
- CHECK FRONT POWER WINDOW MOTOR LH CIRCUIT
- Turn ignition switch OFF.
- Disconnect main power window and door lock/unlock switch connector.
- Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.
Main power window and door lock/unlock switch Front power window motor LH Continuity Connector Terminal Connector Terminal D7 8 D9 2 Yes 11 1 - Check continuity between main power window and door lock/unlock switch harness connector and ground.
Main power window and door lock/unlock switch Ground Continuity Connector Terminal D7 8 No 11
Is the inspection result normal?
YES
Replace main power window and door lock/unlock switch. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.