Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK DOOR SWITCH INPUT SIGNAL
- Turn ignition switch OFF.
- Disconnect malfunctioning door switch connector.
- Check signal between malfunctioning door switch harness connector and ground using oscilloscope.
(+) (-) Signal
(Reference value)Door switch Connector Terminal Front door switch LH B8 3 Ground
7.0 - 8.0 VFront door switch RH B16 3 Rear door switch LH B6 3 Rear door switch RH B17 3
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
GO TO STEP 2 .
- CHECK DOOR SWITCH CIRCUIT
- Disconnect BCM connector.
- Check continuity between door switch harness connector and BCM harness connector.
Door switch BCM Continuity Connector Terminal Connector Terminal Front door switch LH B8 3 M100 47 Yes Front door switch RH B16 45 Rear door switch LH B6 48 Rear door switch RH B17 46 - Check continuity between door switch harness connector and ground.
Door switch Ground Continuity Connector Terminal Front door switch LH B8 3 No Front door switch RH B16 Rear door switch LH B6 Rear door switch RH B17
Is the inspection result normal?
YES
Replace BCM. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.
- CHECK DOOR SWITCH
Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Replace malfunctioning door switch.
- CHECK INTERMITTENT INCIDENT
Refer to INTERMITTENT INCIDENT .
Inspection End.