DECEL G Sensor Calibration
CAUTION:
Always use CONSULT for the decel G sensor calibration. (It cannot be adjusted other than with CONSULT.)
NOTE:
Yaw rate/side/decel G sensor calibration is performed when performing the decel G sensor calibration.
- CHECK THE VEHICLE STATUS
- Steer the steering wheel to the straight-ahead position. Stop the vehicle on a level surface.
- Stop the engine.
- Ignition switch OFF.
Is the vehicle stopped in the straight-ahead position on a level surface?
YES
GO TO 2.
NO
Steer the steering wheel to the straight-ahead position. Stop the vehicle on a level surface.
- PERFORM DECEL G SENSOR CALIBRATION CAUTION:
- Never allow passenger or load on the vehicle.
- Never apply vibration to the vehicle body when opening or closing door during calibration.
CONSULT
- Ignition switch ON.CAUTION: Never start engine.
- Select "ABS", "Work Support" and "DECEL G SEN CALIBRATION" in this order.
- Select "Start".
- After approx. 10 seconds, select "End".
- Ignition switch OFF -> ON.CAUTION: Be sure to perform the operation above.
GO TO 3.
- CHECK DATA MONITOR
CONSULT
- Drive the vehicle. Steer the steering wheel to the straight-ahead position. Stop the vehicle on a level surface.
- Select "ABS", "Data Monitor", "ECU INPUT SIGNALS" and "DECEL G SENSOR" in this order. Check that the signal is within the specified value.
DECEL G SENSOR
: Approx. +/- 0.01 G
Is the inspection result normal?
YES
GO TO 4.
NO
GO TO 1.
- ERASE SELF DIAGNOSTIC RESULT MEMORY
CONSULT
Erase "Self Diagnostic Result" mode of "ABS".
Are the memories erased?
YES
Inspection End.
NO
Check the items indicated by the "Self Diagnostic Result".