Diagnosis Procedure
- CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY
Is the inspection result normal?
YES>>
GO TO 3.
NO>>
GO TO 2.
- CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY CIRCUIT
-
- Turn ignition switch ON.
- Disconnect ECM harness connector.
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
Refrigerant pressure sensor ECM Continuity Connector Terminal Connector Terminal E35 3 F24 43 Existed - Also check harness for short to power.
Is the inspection result normal?
YES>>
Perform trouble diagnosis for power supply circuit.
NO>>
Repair or replace malfunctioning part.
-
- CHECK REFRIGERANT PRESSURE SENSOR GROUND CIRCUIT
Is the inspection result normal?
YES>>
GO TO 4.
NO>>
Repair or replace malfunctioning part.
- CHECK REFRIGERANT PRESSURE SENSOR INPUT SIGNAL CIRCUIT
Is the inspection result normal?
YES>>
GO TO 5.
NO>>
Repair or replace malfunctioning part.
- CHECK INTERMITTENT INCIDENT
- Check intermittent incident. Refer to Refer to Intermittent Incident .
Is the inspection result normal?
YES>>
Replace refrigerant pressure sensor. Refer to Removal and Installation .
NO>>
Repair or replace malfunctioning part.