Component Inspection
- CHECK EGR VOLUME CONTROL VALVE-1
With CONSULT
- Turn ignition switch ON (engine stopped).
- Perform "EGR CONTROL VALVE" in "ACTIVE TEST" mode of "ENGINE" using CONSULT.
- Operate "Up" or "Down", set "EGR VALVE POSITION" to 0 deg, and check value "V1" of "EGR VALVE POSITION SEN".
Does "V1" become 0.5±0.1 V?
>>
GO TO 2.
>>
Replace EGR volume control valve.
- CHECK EGR VOLUME CONTROL VALVE-2
With CONSULT
- Operate "Up" or "Down", set "EGR VALVE POSITION" to 70 deg, and check value "V2" of "EGR VALVE POSITION SEN".
Does "V2" become 3.6±0.25 V?
>>
GO TO 3.
>>
Replace EGR volume control valve. Refer to Exploded View .
- CHECK EGR VOLUME CONTROL VALVE-3
- Turn ignition switch OFF
- Remove EGR volume control valve.
- Check the resistance between EGR volume control valve terminals.
EGR volume control valve Resistance (Approx.) + - Terminal 6 5 1 - 100 Ω
Is the inspection result normal?
>>
GO TO 4.
>>
Replace EGR volume control valve. Refer to Exploded View .
- CHECK EGR VOLUME CONTROL VALVE VISUALLY
Check if any foreign objects interferes with EGR volume control valve.
Is the inspection result normal?
>>
INSPECTION END
>>
Repair or replace error-detected parts. Refer to Exploded View .