Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the affected ignition coil/module.
- Ignition OFF for 90 seconds, disconnect the ECM connector X2.
- Test for an open, a high resistance, a short to ground and for a short to voltage between the ignition coil/module IC circuit terminal C and the appropriate ECM terminal listed below:
- IC 1 circuit: terminal 1
- IC 2 circuit: terminal 53
- IC 3 circuit: terminal 17
- IC 4 circuit: terminal 33
- If a fault is found, repair the circuit as needed.
- Connect the ECM.
- Exchange the affected ignition coil/module with the ignition/coil module of a good cylinder.
- Start the engine and observe the scan tool.
- If the DTC or the misfire transfers with the suspect ignition/coil module, replace as needed.
- If the DTC or the misfire does not transfer with the suspect ignition/coil module, replace the ECM.