Monitor Strategy
| Related DTCs | P0715: Input Speed sensor (NT)/Range check P0717: Input Speed sensor (NT)/Verify pulse input |
| Required sensors/Components | Input Speed sensor (NT), Output Speed sensor (NC) |
| Frequency of operation | Continuous |
| Duration | P0715: 4.5 seconds P0717: 5 seconds |
| MIL operation | Immediate |
| Sequence of operation | None |