Solenoid Pull-In Coil Test

Connect 2 battery negative leads to main terminal and ground. Connect a 12-volt battery positive lead to solenoid "ST" terminal. See Fig 1. Plunger should extend firmly. If not, replace solenoid.

Fig 1: Solenoid Pull-In Coil Test Connect battery positive to "ST" terminal.