Main Switch
Remove switch from instrument panel. With switch in the "OFF" position, check that there is continuity between terminals "C" and "D", and terminals "A" and "B". Terminal "E" should be open. With switch in "ON" position there should be continuity between terminals "C", "D", and "E", and between terminals "A" and "B". See Fig 1 .